Inverted-V Dipole Installation & RF Calculator

CAD + NEC Engine

Slope-Compensated Field Rigging, Resonant Wire Sizing, Apex Impedance & 3D-Slice Pattern Analyzer

Quick Presets:

1. RF & Radiator Parameters

NEC-2 Wire Model
MHz
1.8 MHz (160m) λ = 137.57 ft 54.0 MHz (6m)
Baseline Quarter-Wave Formula 234 / f(MHz) ft
%

Compensates for tower width capacitance, apex V-droop mutual coupling, & wire velocity factor.

32' 0.8"
ft
Uncheck Auto-Resonant to enter custom wire length Resonant (jX ≈ 0)
ft
0' 6.0" per leg
ft
2' 0.0" extra rope

2. Tower, Apex Angle & Site Limit

Rigging Geometry
ft
55' 0.0" 0.40 λ above base
Radiator Attachment Angle at Tower θ_apex = 2 × α
deg
deg
Steep V (15° / 30°) 45° / 90° Optimal Match Flat-Top (85° / 170°)
ft
Max 60' 0.0" from tower base Both poles within site limit

3. Poles & Ground Elevation

Slope Compensation
Pole 1 (Left Leg) Downhill (-2.0 ft)
ft
ft
- Downhill (Lower) 0 (Level) + Uphill (Higher)
Pole 2 (Right Leg) Uphill (+3.0 ft)
ft
ft
- Downhill (Lower) 0 (Level) + Uphill (Higher)
Radiator Wire Cut Spec
Single Leg Wire Needed (L_rad)
32.07 ft 32' 0.8"
Total Dipole (2×L) 64.14 ft
Comp. Trim Removed -0.65 ft
Feedpoint Impedance (Z_in)
Complex Input Impedance @ Apex
51.4 - j1.2 Ω
50Ω VSWR 1.04 : 1
75Ω VSWR 1.46 : 1
Return Loss 34.2 dB
Radiation & Propagation
Peak Elevation Take-Off & Gain
42° 6.1 dBi
Wire Resonant Freq 7.150 MHz
Azimuth Circularity ±3.8 dB

Pole 1 (Left Side) Rigging Specs

Vertical Drop ΔZ₁ = 50.00 ft

PASS: WITHIN SITE
Tower Base to Pole 1 (D₁) 50.00 ft 50' 0.0" horizontal
Extra Support Rope (L_rope1) 38.14 ft 38' 1.7" (+knot: 40' 1.7")
Total Slant Span (Apex to Pole 1): 70.71 ft (70' 8.5")
Ground Taped Slope Distance: 50.04 ft (50' 0.5")
Mason String Field Guide: Tie @ 4ft on tower → hits 6.0ft on Pole 1

Pole 2 (Right Side) Rigging Specs

Vertical Drop ΔZ₂ = 45.00 ft

PASS: WITHIN SITE
Tower Base to Pole 2 (D₂) 45.00 ft 45' 0.0" horizontal
Extra Support Rope (L_rope2) 31.07 ft 31' 0.8" (+knot: 33' 0.8")
Total Slant Span (Apex to Pole 2): 63.64 ft (63' 7.7")
Ground Taped Slope Distance: 45.10 ft (45' 1.2")
Mason String Field Guide: Dirt @ 45ft → hits 3.0ft on Tower

Interactive Site Elevation & Rigging CAD Schematic

True-to-scale geometry showing tower, sloped terrain, radiator wires, end insulators, and support ropes

Radiator Wire (L_rad) End Insulator (L_ins) Support Rope (L_rope) Level Mason String Site Boundary (D_max)

Azimuth Radiation Pattern (dBi)

Shows V-droop end-fire vertical polarization filling broadside nulls

Top-Down View
Total Gain Horiz. Pol (Broadside) Vert. Pol (Off-Ends)

Elevation Take-Off Pattern (dBi)

Ground-reflection lobes based on H_eff = 0.34 λ

Regional + DX
Broadside Lobe Off-End Lobe Peak Take-Off Angle